 Click for Instructions

Cable Selection Guide WET BED CABLE - 1/2" min. Floor Warming NET AREA SQ/FT |
CABLE, SQ FT |
MODEL |
WATTS@230V |
16-24 |
TXLP-300 |
300 |
25-33 |
TXLP-400 |
400 |
34-41 |
TXLP-500 |
500 |
42-50 |
TXLP-600 |
600 |
51-55 |
TXLP-700 |
700 |
56-85 |
TXLP-850 |
850 |
86-105 |
TXLP-1000 |
1000 |
106-125 |
TXLP-1250 |
1250 |
126-140 |
TXLP-1400 |
1400 |
141-175 |
TXLP-1750 |
1750 |
176-220 |
TXLP-2200 |
2200 |
|
Cable Selection Guide for Floor Heating Cable
STEP #1 Multiply the Width(w) x Length(l) of the room to
determine the Total square footage of the area.
Total sq. ft.__________________
STEP
#2 Subtract the Total square footage of the items that are
fixed, such as toilet, vanity, bath or any other fixed item that will
not be heated.
Less fixed areas_______________
STEP
#3 Refer to the LAST column in the selection table and find
your square foot range. Select the appropriate cable by MODEL number.
NET TOTAL=________________
EXAMPLE
Total sq. ft. area (W x L) = 100 sq. ft.
Less fixed
Toilet (3'x3') = - 9 sq. ft.,
Vanity
(2'x5') = -10 sq. ft, Tub (3'x6') = -18 sq. ft.
--------------
Subtract -37 sq. ft.
-------------
Total NET floor area = 63 sq. ft.
Refer to CABLE SELECTION GUIDE for MODEL selection:
Choice = Cable #TXLP-850
|